Enter the area you want to heat, your winter climate and how well the house holds heat. You get a rough heat-need range in Btu per hour to compare with the overall heat output range on a stove’s spec sheet. It runs in your browser; nothing is stored.
How the math works
- Heat need (Btu/h) = area × planning factor × (70°F − winter design temperature), shown as a range of ±20% and rounded to 100.
- Planning factors (0.25 tight, 0.35 average, 0.5 drafty, in Btu/h per sq ft per °F) and the example climate temperatures are our own rough assumptions for a first look. They are not from a published standard.
- A room-by-room heat-loss calculation (ACCA Manual J) by a heating professional is the reliable method. Your local code office can tell you the heating design temperature for your county.
Compare the result with a stove’s overall heat output range and EPA loading volume, not its heating-area claim. Drolet, for example, defines heated area as the stove’s “capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.” See what size wood stove do I need for a walk-through.